Troubleshooting
56 ecoTEC plus installation and maintenance instructions 0020134823_01
14
14.2.2 Overview of status codes
Display Meaning
Heating mode
S00 Heating, no heat demand
S 02 Heating mode pump flow
S03 Heating mode, ignition
S04 Heating mode, burner on
S05 Heating mode, pump/fan overrun
S06 Heating mode, fan overrun
S 07 Heating mode, pump overrun
S08 Heating, remaining locking time in xx minutes
S09 Heating mode measuring programme
Special cases
S30 Room thermostat is blocking heating mode
S 31 Summer mode active or no heat requirement from eBUS
controller
S32 Operation block function due to different fan speed
S34 Frost protection mode active
S36 Target value of the eBUS controller is < 20 °C and is
blocking heating mode
S37 Fan waiting period: Fan failure in operation
S 39 Contact thermostat/"burner off contact" has responded
S40 Comfort protection mode is active: Unit running with
limited heating comfort
S41
Water pressure > 0.2 MPa (2 bar)
S42 Flue non-return flap return signal blocks burner opera-
tion (only in connection with VR40 accessory) or con-
densate pump faulty, heat requirement is blocked
S53 Unit is within the waiting period of the modulation
block/operation block function due to low water pres-
sure (flow-return spread too large)
S 54 Unit is within the waiting period of the operation block-
ing function as a result of low water pressure (tempera-
ture gradient)
S 96 Return sensor test running, heating demands are
blocked
S97 Water pressure sensor test running, heating demands
are blocked
S98 Supply/return sensor test running, heating demands are
blocked
14.1 Overview of status codes
14.2.3 Service messages
If the "open-end spanner" maintenance symbol appears
in the display, there is a service message. The maintenance
symbol appears if you have set a maintenance interval, for
example, (¬section12.1.6) and it has elapsed. The boiler is
not in fault mode but continues to operate.
To obtain more information about the service message:
> Call up the "Live monitor" (¬section14.2.1).
If status code S.40 is displayed as well as the maintenance
symbol, the boiler is in Comfort protection mode. This
means that the boiler continues to operate with restricted
comfort after it has detected a fault (e.g. because of a
severe storm).
> In this case, read out the fault memory in order to deter-
mine whether a boiler component is defective
(¬section14.2.6).
If no fault message is present, the boiler will automatically
switch back to normal operating mode after a certain time.
Comfort protection mode may then have been triggered by
a severe storm, for example.