M211861EN-D
User Guide
Vaisala VaiNet Wireless Data Logger
RFL100

Table of Contents

Questions and Answers:

Vaisala VaiNet RFL100 Specifications

General IconGeneral
Measurement ParametersTemperature, Relative Humidity
Protection ClassIP65
Measurement Range Relative Humidity0 to 100 %RH
CommunicationWireless
Battery LifeUp to 10 years
Power Supply2 x AA batteries

Summary

About this document

Version information

Details document revisions, including added content and updated sections for specific firmware versions.

Related manuals

Lists Vaisala documentation and guides relevant to the RFL100 and associated systems.

Documentation conventions

Explains symbols, warnings, and notes used in the manual for clear communication.

Trademarks

Lists registered trademarks and trade names of Vaisala and other companies.

Product overview

RFL100 overview

Introduces the RFL100 as a wireless, battery-powered data logger for Vaisala's viewLinc system.

Probe interface

Details the digital interface between the RFL100 and its probes, including data resolution and information transfer.

RFL100 parts

Identifies and describes the components of the RFL100 data logger, including indicators and buttons.

RFL100 batteries

Explains the main batteries and clock battery types, voltage requirements, and usage precautions for the RFL100.

Battery level indicator

Describes the on-screen symbols indicating the remaining battery capacity and their meanings.

Connection indicators

Explains symbols for data logger, access point, and server, and their connection states.

Connection examples

Illustrates different connection states and scenarios for the RFL100 with access points and viewLinc.

Signal strength indicator

Details the signal strength indicator on the RFL100 display and its meaning for connection quality.

Alarm indicators

Describes the symbols on the RFL100 display that indicate active threshold alarms for channels.

Alarm examples

Provides visual examples of the RFL100 display showing high alarm and high-high alarm states.

Service port

Explains the function and connectivity of the micro-USB service port for firmware updates and power.

Files and folders in USB filesystem

Lists the files and folders accessible via the USB filesystem, including licenses and configuration files.

Data transfer in a VaiNet network

Discusses the power-efficient data transfer mechanisms and intermittent radio connections in the VaiNet network.

Safety

Provides essential safety warnings regarding product documentation, hazards, and handling of magnetic components.

ESD protection

Explains electrostatic discharge risks and precautions to prevent damage to electronic circuits.

Installation

Setting up RFL100

Outlines the initial setup procedures for the RFL100, including single and dual probe configurations.

Setup with one probe

Step-by-step guide for installing and setting up the RFL100 with a single probe, including connection and power-on checks.

Setup with two temperature probes

Instructions for setting up the RFL100 with two temperature probes using a probe splitter accessory.

Mounting RFL100

Details various methods for physically mounting the RFL100 data logger, including screws, cable ties, hooks, and magnetic brackets.

Mounting probes

Provides guidance on attaching various Vaisala probes to the RFL100 or using mounting accessories.

Probe holder ASM213382

Describes the probe holder accessory for securing cable-mounted probes to the RFL100.

Mounting HMP110 probes

Instructions for mounting HMP110 probes, highlighting their stainless steel construction and cable connection requirement.

Mounting HMP115 probes

Details on mounting HMP115 probes, mentioning integration with RFL100 and cable connection options.

Mounting TMP115 probes

Instructions for mounting TMP115 probes, covering their wide-range temperature capabilities and cable connection.

Operation

Probe detection

Explains how the RFL100 detects and validates connected probes at startup, including support for dual probe configurations.

Info mode

Describes the Info mode feature, activated by the Info button, for viewing device status and information.

Remote management

Explains how to remotely manage the RFL100 data logger using viewLinc Enterprise Server software.

Releasing RFL100 from viewLinc Monitoring System

Details the procedures for releasing an RFL100 from its current viewLinc system, locally or remotely.

Vaisala Insight software

Introduces Vaisala Insight software for probe management, calibration, and monitoring, compatible with RFL100 probes.

Maintenance

Cleaning RFL100

Provides instructions for cleaning the RFL100 data logger and its mounting bracket using lint-free cloth and isopropyl alcohol.

Changing the probe filter

Details the process for replacing a damaged or dirty probe filter on the RFL100's probe.

Probe replacement

Outlines procedures for replacing probes in different scenarios: one probe, two probes, or changing probe count.

Probe replacement and viewLinc alarms

Explains how probe replacements trigger alarms in viewLinc and how data is managed during these events.

Replacing a probe when one probe is connected

Step-by-step guide for replacing a single probe connected to the RFL100.

Replacing probes when two probes are connected

Instructions for replacing one or both probes when the RFL100 is configured for dual probe operation.

Changing from one probe to two probes

Guidance on switching the RFL100 setup from single probe to dual probe configuration.

Changing from two probes to one probe

Instructions for switching the RFL100 setup from dual probe back to single probe configuration.

Calibration and adjustment

Explains the importance of checking environmental factors before calibration and defines calibration and adjustment processes.

Calibration and adjustment environments

Discusses suitable environments for probe calibration and adjustment, emphasizing stabilization time.

Adjustment points and requirements

Details the specific adjustment points and requirements for different RFL100 compatible probes.

Field checking using a reference instrument

Describes how to perform a field check by comparing RFL100 readings with a calibrated reference instrument.

Calibration and adjustment using HM40

Step-by-step guide for calibrating and adjusting RFL100 probes using the Vaisala HM40 handheld meter.

Calibration and adjustment using M170

Instructions for calibrating and adjusting RFL100 probes using the Vaisala M170 measurement indicator.

Adjusting measurement using Insight software

Details on adjusting humidity or temperature measurements of probes using the Vaisala Insight software.

Changing RFL100 batteries

Provides instructions for replacing the main AA batteries in the RFL100 data logger.

Changing RFL100 clock battery

Step-by-step guide for replacing the 3 V lithium button cell clock battery in the RFL100.

Updating RFL100 firmware

Instructions for updating the RFL100 firmware using a computer and USB connection, including necessary precautions.

Troubleshooting

Problem situations

A troubleshooting table addressing common problems like error codes or the RFL100 not appearing in viewLinc.

Error codes

Lists RFL100 error codes, their causes, and recommended actions for resolution.

Verifying operation of RFL100

Steps to verify the correct operation of the RFL100, checking battery status and measurement readings.

Downloading data using service port

Instructions for downloading log files (Log_1h.txt, Log_24h.txt, Log_30d.txt) via the service port.

Performing a factory reset

Detailed procedure for performing a factory reset on the RFL100, including when it might be necessary.

Technical data

RFL100 technical specification

Provides detailed specifications for the RFL100's wireless capabilities, memory, and operating environment.

RFL100 compatible probes technical specification

Technical specifications for various RFL100 compatible probes, including measurement performance and mechanical details.

Accessories and spare parts

Lists available accessories and spare parts for the RFL100 and its compatible probes, including item codes.

Dimension drawings

Provides dimension drawings for the RFL100 data logger and its mounting bracket.

Technical support

Warranty

Outlines the standard warranty terms and conditions, including exclusions and limitations.

Recycling

Provides instructions for recycling the data logger and its batteries, and adhering to disposal regulations.