TideMaster - Operating Manual: MANUAL-1094978189-1 | issue: 1.1
3.5.3 Scenario C
Druck Pressure Transducer Fitted
Bluetooth On Every burst
Display Period = 5s
Gill Windsonic Not Fitted
Mode
Pattern
Battery Life
B1
30 seconds per 1 minute
13 days
B2
40 seconds per 6 minutes
58 days
B3
40 seconds per 10 minutes
95 days
B4
40 seconds per 15 minutes
140 days
B5
60 seconds per 30 minutes
182 days
3.5.4 Scenario D
Druck Pressure Transducer Fitted
Bluetooth On Every burst
Display Period = 5s
Gill Windsonic Fitted
Mode
Pattern
Battery Life
B1
30 seconds per 1 minute
4.7 days
B2
40 seconds per 6 minutes
20 days
B3
40 seconds per 10 minutes
34 days
B4
40 seconds per 15 minutes
51 days
B5
60 seconds per 30 minutes
67 days
All battery calculation figures are estimated, and may vary according to deployment temperature and
the inherent battery variability.
Valeport accepts no liability for the failure of a battery to last for the expected lifetime.