9.3 Fitting the terminal guard.
Fold the terminal guard as shown in figure 17.
Place the guard centrally over the flue terminal.
Holding the guard in position and using it as a
template, mark on the wall the positions of the four
fixing holes.
Remove the guard. Drill and plug the holes with
the four plugs supplied.
Replace the guard and refix with four woodscrews
supplied.
10. GAS CONNECTION
10.1 Connecting the gas supply pipe.
Complete the supply pipe connection
For concealed rear connection, the pipe run should have been extended as in
section 7 of this guide. Connect the inlet ‘T’ connector to the appliance inlet pipe.
For Side Connection, the pipe should be routed to pass through a cut-out at the
side of the casting or case. For right side connection, the pipe should also be
formed to clear the control unit. Connect the inlet ‘T’ connector to the appliance
inlet pipe.
Pressure test the installation pipework for gas soundness in accordance with the
current edition of BS 6891.
INSTALLER GUIDE
Page 28
© Baxi Heating U.K. Limited 2010.
Figure 17. Terminal guard

Table of Contents

Related product manuals