5.9 Installation options.
5.9.1 The appliance can be installed into the following:
a) A minimum 4.5in rebate surround or Valor Fires 5in. spacer kit Part No
0595121. Where either of these are mounted to a combustible wall make sure that
there is no combustible material or combustible cladding in the area indicated on the
wall fixing template.
b) A 2in rebate surround in conjunction with the Valor Fires 3in. spacer kit Part No
0595131. Where the surround is mounted to a combustible wall make sure that there
is no combustible material or combustible cladding in the area indicated on the wall-
fixing template.
c) Recessed into a builder’s opening or cavity of a non- combustible wall. The
cavity can be elevated. The minimum cavity size is shown in figure 2. A lintel may be
required above the recess opening. If in doubt seek expert building advice. Lintel
construction details are given in section 8 of this guide. This appliance must not be
recessed into a combustible wall.
5.9.2 A concealed gas supply connection can be made through the rear left panel.
Visible front connection can be from the left or right side.
5.10 Terminal guard and terminal clearances.
5.10.1 A terminal guard is supplied with this appliance.
In England and Wales the Building Regulations require a terminal guard to be fitted if
the terminal could come into contact with people near the building or be subject to
damage.
In the republic of Ireland the installation must also conform to the relevant parts of the
current edition of IS 813 “Domestic Gas Installations”
We recommend that the guard is fitted where contact with or damage to the terminal
is possible even if regulations do not demand it.