EasyManua.ls Logo

Valor Fires 942 - 2 Appliance Data and Efficiency

Valor Fires 942
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
drinking in the work area and always wash your hands before eating or
drinking.
This appliance does not contain any component manufactured from asbestos
or asbestos related products.
2. APPLIANCE DATA AND EFFICIENCY
2.1 General information.
*When converted using kit 0595211.
The appliance information label is located on a plate at the base of the fire.
2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below :
Model
Efficiency % (Gross)
942 55
942 when converted to LPG. 53
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
Page 8
© Baxi Heating U.K. Limited 2009.
INSTALLER GUIDE
Gas Natural (G20) Propane (G31) *
Inlet Pressure 20mbar 37mbar
Input - Max. (Gross) 6.85kW (23,400 Btu/h) 6.7kW (22,860 Btu/h)
Input - Min. (Gross) 2.7kW (9,410 Btu/h) 4.3kW (14,670 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0 mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0 mbar
(14.85 ± 0.4in w.g.)
Gas Connection 8mm pipe 8mm pipe
Burner Injector Cat 82 - 074 Size 132
Pilot & Atmosphere Sensing
Device
Copreci Ref. O.D.S
21500/166
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 -02 injector
Ignition
Electronic
(Battery 9V PP3)
Electronic
(Battery 9V PP3)
Aeration Factory set Non-adjustable

Table of Contents