Heater Mode
Press to cycle through the heat output options: ON-OFF-AUTO.
To switch between ºC/ºF, press and hold or button for 3 seconds.
Press and buttons to adjust the temperature you want the room to
reach, from 5 to 40 ºC (41 to 104 ºF).
NOTE: It is normal for the fan heater to stop running for periods of
time. This happens because the room temperature is at or above the
temperature set on the remote control.
Timer Mode
NOTE: This setting is only for operating in normal mode. It allows the
appliance to go into standby after a set period of time.
Press to cycle through the settings from 0.5 hour to 10 hours, and then OFF.
Adaptive Start Control
Learning from the previous heating cycle enables the appliance to judge
the appropriate advance time to turn on the heater to ensure that the set
temperature is reached at the set time. For example, if your timer is set to
start at 18:00 (6 pm) and temperature is set to 23 °C (73 ºF), the fire may for
example come on at 17:30 (5:30 pm) to ensure the room is 23 °C at 18:00.
Window Open Detection
When the transmitter detects a rapid drop in room temperature, it will be
judged as a window open, the warning icon will be displayed and the heater
will be turned off automatically.
After the indoor temperature has risen or a manual override of the warning
(by operating remote control) has been done, the fire will return to normal
working state.