4.8.5 Engine
4.8.5.1 Bleeding the fuel system
After changing the fuel filters or if the engine has ran out of fuel the fuel system
has to be bled.
2
1
GUID-647FB64A-BC65-43E4-856B-A428F80A6D02
1. Hand pump
2. Bleeding plug
WARNING: Do not work on the common rail high pressure fuel system
when the engine is running. Wait at least 30 seconds after stopping
the engine. The first high pressure component has to be loosened
slowly, so that the pressure inside the fuel system can adjust to
ambient pressure. If the jet of high pressure fuel contacts your skin,
fuel penetrates the skin causing severe injuries. Get medical help
immediately!
WARNING: Only an authorised person is allowed to repair the fuel
system.
IMPORTANT: Do not use the hand pump when the engine is running. Do not use
any tools or excessive force on the hand pump.
1. Open the bleeding plug.
2. Put a transparent hose in the plug hole and lead it into a suitable container.
4. Maintenance
- 337 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Valtra T214 and is the answer not in the manual?

Valtra T214 Specifications

General IconGeneral
TransmissionPowershift
Max Speed50 km/h
Engine Type6-cylinder diesel
Displacement7.4 liters
EngineAGCO Power
Rear Lift Capacity9500 kg
Lift Capacity9, 500 kg
Wheelbase2.995 m
Hydraulic SystemLoad-sensing
Tire OptionsMultiple options available

Related product manuals