Operating & Mounting instructions – 8 074 143.03/03 – Page 59
Parameters
Software lock, Factory default
b031 Software lock VIC 00 to 10 01
Locks or releases adjustment of parameters.
Setting Function
00 All parameters locked (excepted parameter b031) as long as there is a lock signal
at the control terminals (set one of the parameters C001...C005 to position 15)
01 All parameters locked (excepted parameter b031 and frequency reference value
F001) as long as there is a lock signal at the control terminals (set one of the
parameters C001...C005 to position 15)
02 All parameters locked (excepted parameter b031) as long as parameter b031 is set
to position 02
03 All parameters locked (excepted parameter b031 and frequency reference value
F001) as long as parameter b031 is set to position 03
10 All parameters locked (excepted parameter b031) and all parameters, which can be
adjusted during operation, are active as long as parameter b031 is set to 10.
b084 Factory default setting VIC 00 to 02 00
Setting Function
00 Delete error message
01 Reset to factory default (see “Commissioning”)
02 Deletes error message and resets to factory default
b085 Kind of factory default VIC 00 to 03 01
Selection of factory defalt.
Setting Function
00 -
01 Factory default of parameters for Europe
02 Factory default of parameters for USA
03 -