16 Kienzle MTCO 1324
Trouble shooting
Only after having remedied the error cause,
e.g. in case of an operating error, will the
message automatically be deleted.
Updating the chart carrier
1. Open the drawer and remove both
charts.
2. Close the drawer again.
¾ The MTCO will automatically update
the time of the chart carrier, and the
error symbol and the time will then
stop to flash.
3. Open the drawer and insert new charts
if necessary. The MTCO 1324 will be
ready for use again.
Displayed messages Code Meaning / measure
OL¬
OLH
OLI
= Error in recording system
(The MTCO will record these errors on the chart,
➥ see page 21.)
OJI
= Error at "B7" v-pulse output
WJ¬¬
= Disconnection towards indicating instrument
WJHI
WNHH
=
=
Error during pulse generator communication
Error in pulse generator key / serial number /
signal
(The MTCO will record these errors on the chart,
➥ see page 21.)
WJ
= Power loss
(Error code cannot be found in the error memory.
The MTCO will record a power loss on the chart,
➥ see page 21.)
In case one of the messages is
shown repeatedly, immediately
consult a VDO service partner!