EasyManua.ls Logo

Vega FIBERTRAC 31 - Page 47

Vega FIBERTRAC 31
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
6 Set up with the display and adjustment module
FIBERTRAC 31 • Probus PA
43833-EN-170126
In menu item "Scaling unit" you dene the scaling variable and the
scaling unit for the pulse rate on the display, e.g. volume in percent.
In menu item "Scaling" you dene the scaling format on the display
and the scaling of the measured values for 0 % and 100 %.
Measured value min.
Measured value max.
To damp process-dependent measured value uctuations, you can
set a time of 0 … 999 s in this menu item.
The default setting is a damping of 0 s.
In the menu item "Lock/unlock adjustment", you can protect the sen-
sor parameters against unauthorized or inadvertent modication. The
sensor is locked/unlocked permanently.
With locked instrument, only the following adjustment functions are
possible without entering a PIN:
Select menu items and show data
Read data from the sensor into the display and adjustment mod-
ule.
Before you lock the sensor in unlocked condition, you can modify the
four-digit PIN number.
Keep the entered PIN number in mind. Operation of the sensor is only
possible with this PIN number.
Setup - AI FB1 - Scaling
unit
Setup - AI FB1 - Scaling
Setup - AI FB1 - Damping
Lock/unlock setup - Ad-
justment

Table of Contents

Other manuals for Vega FIBERTRAC 31

Related product manuals