23
4 Mounting
VEGAFLEX 86 • Probus PA
44232-EN-160518
Keep in mind that below the fastening, a measurement is not possible.
1
2
1
2
Fig. 12: Fasten the probe
1 Measuring probe
2 Retaining sleeve
If there is a risk of the cable probe touching the vessel wall during
operation due to product movements or agitators, etc., the measuring
probe can be strained.
For this purpose there is an internal thread (M12 or M8) in the gravity
weight.
Make sure that the probe cable is only hand tight. Avoid strong tensile
loads on the cable.
Keep in mind that measurement is only possible up to the tensioning
component. For this reason, order the cable probe 270 mm longer.
L = L1 + 270 mm (10.63 in)
1
2
83 mm
(3.27")
L1
8 mm
(0.31")
26 mm
(1.02")
38 mm
(1.50")
ø < 8 mm
(ø < 0.315")
550 mm
(21.65")
M12
M8
Fig.13:Tensioningcomponentforcableversions
1 Holding screw M8
2 Holding screw M12
L1 Max. measuring length
Probe length L = L1 + 270 mm (10.63 in)
Fixing facility