9 Adjustment menu
VEGAPULS 11 • Two-wire 4 … 20 mA
58350-EN-200806
Further recommendations
False signal suppression via adjustment app or PACTware/DTM
Overowbasin
Vessel
Large volume
Partly installed underground
Process/measurement conditions:
Partly strongly agitated surface
Multiplereectionsthroughatvesselceiling
Condensation, dirt deposits on the sensor
Flooding of the sensor antenna
Vessel/Collecting basin
Vessel:
Large volume
Upright cylindrical or rectangular
Process/measurement conditions:
Slowllingandemptying
Smooth medium surface
Condensation
Plastic tank (measurement through the vessel top)
Process/measurement conditions:
Measurement through the tank top, if appropriate to the applica-
tion
Condensation on the plastic ceiling
In outdoor facilities, water and snow on vessel top possible
Further recommendations
With measurement through the tank top false signal suppres-
sion via adjustment app or PACTware/DTM
When measuring through the tank top in outdoor areas protec-
tive roof for the measuring point
Transportable plastic tank (IBC)
Process/measurement conditions:
Materialandthicknessdierent
Measurement through the vessel top, if appropriate to the
application
Changedreectionconditionsaswellasjumpsinmeasured
values when changing vessels
Further recommendations
With measurement through the tank top false signal suppres-
sion via adjustment app or PACTware/DTM
When measuring through the tank top in outdoor areas protec-
tive roof for the measuring point
Gauge measurement in waters
Process/measurement conditions:
Slow gauge change
Extreme damping of output signal in case of wave generation
Ice and condensation on the antenna possible
Floating debris sporadically on the water surface