HP25E / HP30E 6. Graphical control
6-27© VEMAG 2018
6.6.3.4 Pause
Display: Pause
Unit: Milliseconds [ms]
Resolution: 1 ms
Setting range: 0 – 9,999 ms / -1 = single portions
Application: Portioning programs (not for “LPG” or “Continuous” modes)
Enter pause time.
Press Enter.
The minimum pause time is limited automatically depending on the
parameters in Section 6.6.3.5.
If selecting individual portions, you need to activate the knee lever signal
for each portion (AC signal).
6.6.3.5 Linking/clip time/knife/output signal
Display: Linking / clip time / knife / output signal
Unit: Number / Milliseconds [ms]
Resolution: 0.1 / 1 ms
Setting range: 0 – 150/0 – 9,999 ms (default for knife = 50 ms)
Application: Linking, clipping, cutting, lling head
Enter number of links/time.
Press Enter.
If you wish to perform a linking horn test, put a tick in the appropriate eld
by pressing Enter.