HP25E / HP30E 6. Graphical control
6-37© VEMAG 2018
6.6.4.16 Remaining portions
Display: Remaining portions
Unit: Portion
Resolution: 1
Setting range: 0 – 50 / -1 = O󰀨
Application: LPG 208, LPG 209, FSL 210, FSL 211
Enter number of portions still to be produced once casing end
detection is triggered.
0 = The current portion is broken o󰀨.
-1 = Ignore sensor.
Tick the “manual” eld if further portions are to be produced after the
machine has been manually stopped.
Press Enter.
6.6.4.17 Run-on
Display: Wake
Unit: Millimetre [mm]
Resolution: 1 mm
Setting range: 0 (= o󰀨) - 2,000 mm
Application: LPG 202
Enter run-on for the dividing belts to convey the remaining casing out
of the dividing belts.
Press Enter.