HP25E / HP30E 6. Graphical control
6-41© VEMAG 2018
6.6.4.27 Sausages on last hook
Display: Sausages on last hook
Unit: Number
Resolution: 1
Setting range: 1 – 50
Application: AH 204, AH 212
Enter the number of sausages to hang on the last hook.
Press Enter.
Conditions:
Stop counter switched o󰀨
„Hooks per stick“ dened
„Remaining portions“ > “Sausages per hook”
Put a tick in the “Tick” eld to ensure that there is the same number of
sausages on each hook (= all loops on the smoke stick are the same)
once the machine has stopped (e.g. via natural casing end detection).
“Catch residue” (“Sausages per hook” parameter”) is only taken into con-
sideration for this in the event of cancellation (e.g. split casing).
Section 6.6.4.28
6.6.4.28 Sausages per hook
Display: Sausages per hook / Catch residue
Unit: Number
Resolution: 1
Setting range: 1 – 99
Application: AH 204, AH 212
Enter the number of sausages to hang between the hooks.
Press Enter.
If you would like to hang rings, enter "1".
If the last sausages in a casing are to be caught, even if they don’t
form a complete loop, enter a value in the “Catch residue” eld.