HP25E / HP30E 6. Graphical control
6-47© VEMAG 2018
6.6.4.41 Separation valve open
Display: Separation valve open
Unit: Gramme [g]
Resolution: 1 g
Setting range: 0 – 5,000 g
Application:
“Continuous” mode
Enter the weight of the lling quantity for which the separation valve
is to be open during straight lling. The separation valve remains
open until the weight entered has been lled.
Press Enter.
6.6.4.42 Separation valve closed
Display: Separation valve closed
Unit: Gramme [g]
Resolution: 1 g
Setting range: 0 – 15,000 g
Application:
“Continuous” mode
Enter the weight of the lling quantity for which the separation valve
is to be closed during straight lling. The separation valve remains
closed until the weight entered has been lled.
Press Enter.