Hopper Bucket
Switch
Hopper bucket motor
runs but does not
detect the home
switch.
Run Test Hopper Bucket in Test Mode Replace the hopper bucket motor assy.
Temperature
Lockout Error
Door Open Timer
Door was open more
than 10 minutes
during reloading.
The cabinet could not
cool below 41º F. (4º
C)
Service Mode - Diagnostics - Clear the errors. Replace the products from the Temperature lockout
shelves
High
Temperature
Cabinet temperature
remained above 41º
F (4º C) for more than
15 minutes
Service Mode - Diagnostics - Clear the errors. Replace the products from the Temperature lockout
shelves
Power Failure
Vendor lost power for
more than 15
minutes. Cabinet
temperature rose
above 41º F (4º C).
Service Mode - Diagnostics - Clear the errors. Replace the products from the Temperature lockout
shelves
Bad Ambient
Temperature
Sensor
Ambient Temperature
Sensor is not working
Open the door- The Ambient Temperature
Sensor should be fitted at the top-left, front of
the cabinet. (Silver probe with brown wiring)
Check wiring harness for continuity from the probe to
the power supply at botto
m left of cabinet. If Harness is
damaged, replace.
If it is not the harness - replace the Ambient
Temperature Sensor.
Coin Changer
Check that red light is flashing on control board.If light is not flashing, there is no power to board.
Check and replug any unplugged connections.
If fuse is blown replace it.
Replace transformer.
Coin
Communication
Changer
communication error -
no changer
communication for
more than 2 seconds.
Defective acceptor. Replace acceptor.
Tube Sensor Tube sensor is
defective -- reported
by changer.
Check changer tubes for blockage Clear tube blockage. If no blockage is found, replace
changer.