1. Switch OFF the mains supply by turning the ON/OFF switch in OFF position.
2. Wait at least 4 minutes to ensure all internal components have discharged.
3. Unlock and open the cabinet door.
4. By means of a wrench key turn the extension shaft in ON position (clockwise) in order to
power up the iPM200 module.
5. Change the desired parameter accordingly to this chapter. When the parameters are
stored, power off the module by turning the extension shaft in OFF position (counter-
clockwise).
6. Close and lock the cabinet door. Turn the ON/OFF switch in ON position.
Examples of extension shaft
Warning! High Voltage
Possibility of electric shock.
Do NOT touch any other components than the extension shaft
and the iPM200 control panel