iPM 200 generator module
® Vetaphone March 2021 3401201GB
Page 5 of 52
1.1 Warnings
The components of the generator power unit is live when generator
module is connected to the mains.
To get contact with this voltage is extremely dangerous and can cause
death or serious injury.
The control module is isolated from the supply voltage.
If the Vetaphone equipment is used as part of a machine, it is the
machine manufacturer's responsibility that the machine is equipped with
a main switch and pre-fuse that comply with IEC 60947-1 and IEC
60947-3.
To comply with UL/cUL or ETL
The pre-fuses must be a Schneider Electric C25 3P 6KA UL or equal UL
approved
The main switch must be a Ensto KSR3.60/U or equal UL approved
It can be extremely dangerous to touch the electrical parts even when
the mains supply has been disconnected.
Wait at least 4 minutes after the input power has been removed before
servicing the generator module.
Incorrect installation of the generator module may cause damage to the
equipment, serious injury or death. Comply with the safety instructions in
this manual as well as local and national rules and safety regulations.
Please consult the manual