2 Technical data
AC line supply X19 (L1, L2, L3, PE)
iPM200-5
iPM200-10
Supply voltage (L, L, L)
3Ph+PE: 3 x 220-300/380 - 520 VAC +/-10%
Supply frequency
50/60 Hz
Maximum input current
8.7Arms
17.5Arms
Maximum input power
5.75 kVA
11.5 kVA
Displacement Power Factor
> 0.95 at nominal output power
Installation category
II
Pollution degree
2
Operation below 380Vac is possible with reduced load power.
Conforms to UL standard UL 61010-1
UL Standard for Safety Electrical Equipment For Measurement, Control, and Laboratory Use;
Part 1: General Requirements, Issued:2004/07/12 Ed:2 Rev:2008/10/28
Certified to CSA CSA C22.2#61010-1
Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use
Part 1: General Requirements, with general instruction No. 1: 2008/10/28 - (R2009),
Issued:2004/07/12 Ed:2 (R2009)
To comply with UL/cUL
If the Vetaphone equipment is used as part of a machine, it is the machine manufacturer's
responsibility that the machine is equipped with a main switch and pre-fuse that comply with IEC
60947-1 and IEC 60947-3.
The pre-fuses must be a Schneider Electric C25 3P 6KA UL or equal UL approved pre-fuse.
Please consult the
manufacture's
specifications for details regarding installation.
Output data X18 (A1-A4, B1-B4,PE)
iPM200-5
iPM200-10
Output voltage
380 - 520Vrms
Output frequency
12 - 40 kHz
Maximum output current (RMS)
15Arms
30Arms
Maximum output current (Peak)
60Apk
125Apk
Maximum power
5 kW
10 kW
The main switch must be a Schneider Electric 63A 3P V3 or equal UL approved.