7.4 Error indications
When an error occurs, the menu will automatically show the error code
All errors are cleared by pressing the "0" (stop) button. The generator will then return to the Operator
view.
If a remote TF415/iCC7 is connected to the iPM200:
7.4.1 Error codes and troubleshooting
High temperature in
Generator
Check that the internal cooling fans operate correctly, and
that they are not blocked with dirt.
Check for high ambient temperature
Check for easy airflow around the generator.
Overload: Too high output
current from the generator.
Electrode adjusted too close to roller. Overload can also be
caused by a flash over in the treater station
Clean insulators and electrode.
Adjust electrodes, see station manual .
No HF Feedback from
transformer
Clean electrode and insulators, 80% of E-3 errors are
caused by this.
The air gap distance between electrode and backing roller in
the treater station can be too big. Check for flashover at the
electrode (defective HP-cable) or missing ground cable.
Adjust electrodes, see station manual
Station is open when it
should be closed
Close the station and make sure that all the cartridge on the
station are closed.
Check sensor on station and check station cable.
A flashover has occurred
more than 3 times within
one second
Check for pinholes in the roll-covering, burned insulators or
defective HP - cable.
At high humidity the insulators must be dried and cleaned
before start up.
Clean insulators and electrodes with alcohol. Make sure that
any carbon residue is removed from insulators or electrodes
No air flow could be
detected within the blower
start delay (default 20 sec)
Check that the extraction fan works and it’s rotating in the
correct direction.
Check that there is airflow through the station.
If the generator controls the extraction fan, the generator will
flash "stand by" in the ON-button until the airflow is correct.
When the problem is solved the generator automatically starts
up again.
No rotation could be
detected.
On rotation sensor 1
On rotation sensor 2
The minimum speed is lower than set in parameter [1.1.3].
Check that the roller on the treater station is actually moving.
Check connection of the Rotation sensor on X5:3 for rotation
sensor 1
Check connection of the Rotation sensor on X5:4 for rotation
sensor 2