Flush hose and mandrel
10.
Remove the soaked parts and rinse them with
clean water (5 times).
14.2 Disinfection process
The 1. is mixed with 8 liters of warm water
(45~50℃) and 2 packets of disinfectant
(KAY5,28.4/ package) to form disinfectant (the
amount of disinfectant is adjusted according to
the amount of cleaning parts needed).
2. soak the cleaned parts in the mixed
disinfectant.
While soaking the parts, spray the disinfectant
evenly and completely on the surface of the
parts in contact with the ice, such as evaporator
ice grid, ice baffle, ice storage bucket, etc .(the
dead corner can be wrapped with disinfectant
wet rag wrapped in disposable chopsticks
cleaning).