3. Unpack
Before unpacking, check whether the anti-tilt
mark (if any) is in good condition, whether the
outer packing of the machine is in good
condition, and whether the machine model is
in accordance with your purchase;
Open the package to check the appearance
of the machine, take out the accessories and
random documents, and check the packing
list is consistent;
remove the protective film on the housing
(recommended).
If there is any discrepancy or damage, please
contact our company / dealer directly.
4.
Installation Location
The ice maker is not suitable for outdoor
usage, the installation location should not be
closed to heat source or be exposed under
direct sunlight.
The normal working ambient temperature
should be ranged between 10°C~38°C, the
water temperature should be between 5°C~
32°C. If the ice-making machine operates
beyond the above normal temperature range
for a long time, its ice-making capacity may be
affected.
Ice makers should be placed near drinkable
water supply. It is recommended that distance
between ice makers be less than one
meterIce-making machine should be placed
near the drinking water source, recommended
from the ice-making machine within one
meter;
Do not block the ventilation window of the ice
maker. There should be enough air
convection space around the ice maker;
The ice maker can not work at sub-zero
temperatures, to prevent supply line failures,
empty the ice maker when the temperature is
below zero(see “preparation for long-term
storage of ice maker” ").
5. Leveling Adjustment
Screw the adjustable part of the four adjusting
bottom feet to the end, and then rotate the
adjusting bottom foot into the corresponding
installation hole at the four corners of the
bottom plate of the ice machine;
Move the ice maker to the installation position.
Use a horizontal ruler to adjust the level of the
ice maker.
Note
Do not use the method of cushioning
hard objects under the bottom foot to adjust
the level of the ice maker. To ensure that the
ice machine four feet stable contact with the
ground, to prevent machine operation
vibration.