Technical Information
Electrical motorized pan and tilt
with electronic control.
Units available in color and day/night
(NTSC/PAL) formats and a variety of
zoom and feature capabilities.
18-32 VAC (UL listed class 2/3 power
supply).
See Table 4.
Indoor:
Coax, Fiber, UTP: 1.0 A.
ViconNet (TCP/IP): 1.4 A.
Outdoor:
Coax, Fiber, UTP: 1.8 A.
ViconNet (TCP/IP): 2.3 A.
Indoor:
Coax, Fiber, UTP: 24 W.
ViconNet (TCP/IP): 34 W.
Outdoor:
Coax, Fiber, UTP: 50 W.
ViconNet (TCP/IP): 54 W.
Indoor:
Coax, Fiber, UTP: 1.3 btu/min
(0.34 kg-cal/min).
ViconNet (TCP/IP): 1.9 btu/min
(0.49 kg-cal/min).
Outdoor:
Coax, Fiber, UTP: 2.8 btu/min
(0.7 kg-cal/min).
ViconNet (TCP/IP): 3.1 btu/min
(0.77 kg-cal/min).
Note: These figures represent the
conversion of 100% of the electrical
energy to heat. Actual percentage of
heat generated will be less and will
vary from product to product. These
figures are provided as an aid in
determining the extent of cooling
required for an installation.
Video Out: See version type.
Power: 2-position removable screw
terminal block.
Control Input/Output: See version
type.
Relay Output: See version type.
Alarm Input: 8-position removable
screw terminal block.
75 ohms.
F1: 2AG, 1.6 A 250 VAC slo-blo.
F2: 2AG, 2.5 A 250 VAC slo-blo.
FCC Class A.
360°.
-2.5° (-2.5° above horizon) to
92.5° (-2.5° past vertical).
Variable, 0.1 to 360°/sec
(120°/sec in 22X).
Variable, 0.1 to 42°/sec;
enable/disable.
Variable, 0.2 to 150°/sec
(90°/sec in 22X).
Less than 1.8 sec from end to end.
16 max, programmable for size and
titling; capability to be blanked out
(22XEX and 23X only).
79 individual programmable preset
positions.
1 sec nominal.
0.23 degrees maximum in pan
and tilt.
22X: 4 tours available.
22XEX/23X: 8 tours available.
32 programmable events per
tour. Events may be preset
positions with speed control,
alarm acknowledge, dwelltime
control, relay control, call
autotours, tour repeat or another
tour, save/recall camera status.
22XEX/23X: 2 autotours available
with 256 pan, tilt and zoom
functions per autotour.
Programming is done in real time
with joystick and push buttons.
Autotours not available on 22X
model.
4 alarm inputs, individually
programmable.
Functional state enable/disable.
Report state (report on/off).
Active state (high/low).
Mode (manual, momentary or
automatic) with programmable dwell
time control.
Set and reset action (preset solve,
relay on/off, tour, autotour).
Alarm titling.
1 relay output.
Power-on state definition (on/off).
Output type definition (momentary or
latching).
Relay function status titling.
Resistive Load: 1.5A@30 VDC
(max).
Inductive Load: 0.75 A @30 VDC.
On-screen, menu-driven system
allowing full configuration of the
dome.
22XEX and 23X: 16 individual,
programmable, zoom-scalable.
Programmable for camera, preset,
sector, relay and alarms.
Camera: 1 for each.
Preset: 79 maximum.
Sector: 16 maximum (not on 22X).
Alarm: 4 maximum.
Individual type date and time
enable/disable; 20 characters
maximum.
Selectable position.
Three text sizes for top two lines.
Fade capability.
Compass/azimuth, 8 compass
headings (N, NE, E, SE, S, SW, W,
NW). Not available on 22X.
Zoom and Focus Speed:
Sectoring:
Preset Capabilities:
Preset Solving
Speed:
Preset Accuracy:
Tour Capabilities:
Autotour Capabilities:
Alarm Capabilities:
Relay Output
Capabilities:
Control Display:
Privacy Masks:
Screen Titling
Capabilities:
Drive Type:
Camera Types:
Input Voltage:
Maximum Power
Cable Distance:
Current Ratings
(@24 VAC), max:
Power Consumption:
Heat Equivalent:
Standard Connector
Types:
Video Output
Impedance:
Fuse:
Radio
Emission Rating:
w:
Video Tilt View:
Pan Speed:
Autopan Speed:
Tilt Speed:
ELECTRICAL
Video Pan Vie
OPERATIONAL
XX134-01-00 Rev 205 SurveyorVFT Camera Dome System Technical Information 63