4000 Series Vandal Resistant Digital GSM Audio Intercom with Proximity
4000 Series Vandal Resistant Digital GSM - Technical Manual
SHUTDOWN AND RESTART RBT
This command feature allows the digital GSM to be remotely shutdown and then rebooted again. The following command can be
sent to the GSM intercom.
1111RBT Shutdown and restart the digital GSM intercom.
IMPORTANT NOTE: This feature should not be confused with the ‘hard-wired’ reset (described on page 21). The RBT function
simply powers down the digital GSM panel and then powers it back up again.
The following commands are reserved for the technical department for interrorgating the digital GSM when testing and applying
specic additional features that are not covered in this technical manual. For the application of these commands please contact
Videx Technical on tel: 0191 224 3174. For overseas customers please contact Videx customer support on tel: (+39) 0734 631 699.
INITIATE A SPECIAL COMMAND PRG
This is an advanced feature of the system which can allow an AT format command to be sent to the OEM GSM module.
1111PRG(command) Send an AT command to the OEM module.
AT COMMAND TO SEND AT START UP AT1, AT2 AND AT3
The AT commands AT 1, AT2 and AT3 are advanced commands of the digital GSM that allows additional features to be incorprated
into the module for testing purposes and include additional features for a specic application that is not already covered in this
manual. The following commands can be sent to the digital GSM.
1111AT1”ATxxxxxx”? Include any AT command for AT1.
1111AT2”ATxxxxxx”? Include any AT command for AT2.
1111AT3”ATxxxxxx”? Include any AT command for AT3.