EasyManuals Logo

Videx 4812 User Manual

Videx 4812
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
66251750-EN - V1.0 - 05/06/17
45
4000 Series Vandal Resistant Digital GSM Audio Intercom with Proximity
4000 Series Vandal Resistant Digital GSM - Technical Manual
Programming via Text Message
PROGRAMMING THE DIGITAL GSM INTERCOM
Programming the Digital GSM can also be carried out by sending text (SMS) messages.
IMPORTANT NOTE: When you are required to use “ in a text message it is very important to use the correct symbol and not for
example ‘ (or two ‘ single apostrophes side by side which you will see look the same but will be interpreted dierently by the
digital GSM panel).
PROGRAMMING BY TEXT MESSAGE
Programming by text message is a simple way to customise the settings of the digital GSM panel and to add or delete apartment
programming remotely. This can include changing apartments telephone numbers, access codes, names or other settings. If you
have a large number of telephone numbers to enter you may nd programming easier with the GSMSK PC software.
Simply send texts in the following format shown below to the telephone number of the SIM within the digital GSM panel:
<4 DIGIT MASTER CODE> <3 DIGIT FUNCTION CODE> <OPTIONAL DATA> <OPTIONAL ?>
4 DIGIT MASTER CODE This code prevents unauthorised access to the programmable features of the system. The code
must be four digits long but can be any combination using digits 0 – 9. The default master code
is 1111 and will be used for all examples in this manual.
3 DIGIT FUNCTION CODE The 3 digit function code identies the programmable feature to be changed. The code must
be in capital letters. The following table lists the available codes.
DESCRIPTION CODE EXAMPLE SETTINGS DEFAULT PAGE
Programming and storing user
information in a new memory
location
MEM 1111MEMnnn”1stNo.,”Div1”,
“Div2”,”Div3”,AptNo.,”Code”,
DTO,TB,”Name”
* see below n/a 47 - 48
Store or change an apartment
code
STC 1111STCn:”cccccc” n = <apt no.>
cccccc = code
n/a 48
Enable/disable an apartment
DTO setting
STO 1111STOn:O n = <apt no.>
O = 0 or 1
n/a 49
Assign a timeband TB to an
apartment
STB 1111STBn:B n = <apt no.>
B = 1-9
n/a 49
Store or change an apartment
name
STT 1111STTn:”tttttttttttttttt n = <apt no.>
tttttttttttttttt =
Name. Use a > to
represent a space
n/a 49 - 50
Store a primary telephone no. STN 1111STNn:”yyyyyyyyyyy” n = <apt no.>
yyyyyyyyyyy =
telephone no. 30
digits max.
n/a 50
Store divert 1 telephone no. STD 1111STDn:”yyyyyyyyyyy” n/a 50
Store divert 2 telephone no. STE 1111STEn:”yyyyyyyyyyy” n/a 50
Store divert 3 telephone no. STF 1111STFn:”yyyyyyyyyyy” n/a 50
Set call time SPT 1111SPTnnn nnn = 001 - 255 040 (40s) 51
Set relay time RLT 1111RLTnnn nnn = 001 - 255 005 (5s) 51
Set auxiliary output AO time A1T 1111A1Tnnn nnn = 001 - 255 005 (5s) 51
Set auxiliary output AO mode A1M 1111A1Mnnn nnn = 000 - 001 001 51
Keep connection facility NOD 1111NODnnn nn = 01 - 99 0 (disabled) 51 - 52
Divert time DIT 1111DITnn nn = 01 - 99 15 (15s) 52
Check GSM signal strength SIG 1111SIG? n/a n/a 52
Check software version VER 1111VER? n/a n/a 52
Forced dial/dial a number DLE 1111DLE”123” n/a n/a 52
Change 4 digit master code CDE 1111CDE1234 Any 4 digits 1111 53
Change 4 digit admin code CDA 1111CDA1234 Any 4 digits 2222 53
Change 4 digit trade code CDT 1111CDT1234 Any 4 digits 0000 53
Trigger the relay RLY 1111RLY n/a n/a 53
Trigger auxiliary output AO A1O 1111A1O n/a n/a 53