4000 Series GSM Audio Intercom - Technical Manual
4000 Series GSM Audio Intercom with Proximity
TERMINAL CONNECTIONS
Connection Description
+ 12-24V AC or DC power input
- 0V power input
C1 Relay 1 common connection
Relay contacts:
3A@24Vac/dc
NO1 Relay 1 normally open connection
NC1 Relay 1 normally closed connection
C2 Relay 2 common connection
NO2 Relay 2 normally open connection
NC2 Relay 2 normally closed connection
C3 Relay 3 common connection
NO3 Relay 3 normally open connection
NC3 Relay 3 common connection
SW1 Switched 0V input to trigger relay 1
SW2 Switched 0V input to trigger relay 2
TECHNICAL SPECIFICATION
Working Voltage : 12V - 24Vac/dc +/- 10%
Current (standby) : 20mA
Current (during operation) : 70mA (max.)
Dry Contact Relay : 3A @ 24Vac/dc (max.)
Working Temp. : -10 +50
o
C
CONNECTING THE CODELOCK TO THE GSM INTERCOM
Follow the connections as shown in Fig.14 when connecting the Art.4800M codelock to the Art.4810 GSM intercom.
*
2
*
1
*
3
Fig. 14
*1 - Remember to set the Art.4800M relay time to a shorter time than that of the Art.4810 GSM intercom relay time.
*2 - If connecting the Art.4810 GSM PRO intercom to a gate controller then please refer to page 20 for correct wiring conguration.
*3 - Set the Art.4810 GSM intercom relay time to a shorter time than that of the Art.4800M relay time.
for fail safe lock wiring
move lock wire from
NO to NC and set MOV1
jumper to NC1 position
Technical Information