PAGE 42 of 80 VX2200 TECHNICAL MANUAL VER1.4
Privacy duration time (Factory default = No time out)
Press and hold (for approx 10 seconds) the “
” button until the LED next to the button illuminates
and the unit beeps.
Each time the “
” button is pressed, it will increase (starting from 0) the privacy duration by 15
minutes.
Press until the required duration has been reached, when reached, wait 5 seconds for a beep and
the LED turning OFF.
The new time will be stored.
To set the privacy with no time out (privacy enabled or disabled by pressing the “
” button), don't
press any buttons once in privacy programming mode and wait 5 seconds for the beep and LED to
go off.
Call tone melody (Factory default = melody 1)
Press and hold “●●” (or “
“on the SL5478) for approx 10 seconds until the LED next to the button
illuminates and the unit plays the current programmed melody.
Press again the “●●” button (or the “
“ on the SL5478) to listen to the available melodies
(maximum 9). Once the chosen melody has been reached, wait 5 seconds for a beep and the LED
turning OFF.
The new melody will be stored
Video monitor (SL5478)
The SL5478 is a slimline version of the 5478. This model is surface mount only and unlike the 5478 does not
require a separate mounting plate. Connections, programming, and functions are the same as the 5478 with
the exception of the “●●” button which is non-latching on the SL5478. The “
“ button is also used instead of
the “●●” button when programming the call tone melody. The 4 way dip switch is also different to the 5478 as
shown below.
4 WAY DIPSWITCH
1 2 3 4 Video Mode
ON OFF ON ON Coaxial video (V2 = V, GND = Screen)
OFF ON ON ON Balance video (V1 & V2)
Technical Specifications
Addressing range : from 1 to 180 (BIN code)
Stand-by absorption : approx 12mA standby on 12V input
Call absorption : approx 70mA max on 12Vdc input (During a call)
: approx 250mA max on 20Vdc input (During a call)
Working temperature : -10 +50 C°