Checking the fuse
1.
B
F1
4.
2.
3.
Fig. 44
1.
Turn off the ON/OFF switch
B
.
2. Remove the programming unit.
3. Pivot the HBMU heat management unit down.
4.
Remove cover
A
.
5. Check fuse F1 (see connection and wiring dia-
gram).
Danger
Incorrect or improperly fitted fuses can lead
to an increased risk of fire.
Insert fuses without using any force. Posi-
tion fuses correctly.
Only use structurally identical types with
the specified response characteristics.