Installation and service instructions
for contractors
VIESMANN
Vitodens 050-W
Type B0HA, B0KA, BPKA, 3.2 to 25 kW
Wall mounted gas condensing boiler
Natural gas and LPG version
Type B0KA-M (for multiple connection), 7.0 to 25 kW
Wall mounted gas condensing boiler
Natural gas and LPG version
Gas Council No.
B0KA: 47-819-55, 47-819-57
B0KA-M: 47-819-56
VITODENS 050-W
6179762 GB 10/2022
Please keep safe.

Table of Contents

Other manuals for Viessmann B0KA

Questions and Answers

  • R
    richard84Sep 13, 2025
    What does fault code 18 mean on Viessmann B0KA?
    • L
      Lori WestSep 13, 2025
      Fault code 18 on your Viessmann Boiler indicates a lead break in the outside temperature sensor. Check the outside temperature sensor and lead.
  • A
    Alex FoxAug 25, 2025
    What to do if my Viessmann B0KA Boiler shows fault F4?
    • S
      Sandra JonesAug 25, 2025
      If your Viessmann Boiler displays fault code F4 and there's no flame signal, you should inspect the ignition/ionisation electrode and its connecting cables. Also, verify the gas pressure, gas train, ignition components, ignition module, and ensure the condensate drain is clear.
  • M
    Mark Strickland Jr.Aug 25, 2025
    How to fix fault F2 on Viessmann B0KA Boiler?
    • W
      William NicholsAug 26, 2025
      If your Viessmann Boiler is showing fault code F2, which indicates the temperature limiter has responded, you should: 1. Check the heating system fill level. 2. Check the circulation pump. 3. Vent the system. 4. Check the temperature limiter and connecting cables.
  • A
    Anthony WattsSep 23, 2025
    How to solve Viessmann B0KA control unit not increasing set value?
    • B
      Brian UnderwoodSep 23, 2025
      To address the issue of the control unit not increasing the set value on your Viessmann Boiler, increase the set value and ensure heat is drawn off.
  • E
    Eric HernandezSep 14, 2025
    How to solve control unit issues with no increase set value on Viessmann B0KA?
    • K
      Krista CrawfordSep 14, 2025
      To address control unit issues with no increase in set value on your Viessmann Boiler, increase the set value and ensure that heat is being drawn off.
  • C
    Carol WilliamsSep 23, 2025
    Why Viessmann B0KA Boiler has no DHW heating with error code 51?
    • D
      Darrell MillerSep 23, 2025
      If your Viessmann Boiler is not heating domestic hot water (DHW) and showing error code 51, it could be due to a short circuit in the outlet temperature sensor. Check the sensor (see page 66).
  • M
    michaelmccartySep 6, 2025
    What does fault E5 mean on a Viessmann Boiler?
    • Z
      Zachary AndersonSep 7, 2025
      If your Viessmann Boiler displays fault code E5, indicating an internal fault, you should check the ionisation electrode and the connecting cables.
  • R
    Ryan BrownSep 7, 2025
    What does fault F5 mean on Viessmann B0KA?
    • K
      Kelly JonesSep 7, 2025
      If your Viessmann Boiler displays fault code F5, indicating an internal fault, you should check the ignition electrodes and connecting cables.
  • M
    Mrs. Brittany HuffmanSep 23, 2025
    What to do if Viessmann Boiler fan doesn't start?
    • J
      Joshua BrownSep 23, 2025
      If the fan in your Viessmann Boiler doesn't start after approximately [ ], check the fan, fan connecting cables, fan power supply, and fan control.
  • A
    Alyssa Lin MDAug 31, 2025
    How to resolve fault 52 on Viessmann Boiler?
    • E
      Erica ValdezAug 31, 2025
      If your Viessmann Boiler displays fault code 52, which indicates a short circuit in the flow sensor, you should check the connections and lead. If necessary, replace the sensor.

Viessmann B0KA Specifications

General IconGeneral
ModelB0KA
CategoryBoiler
ModulationUp to 1:6
Fuel TypeNatural Gas
EfficiencyUp to 98% AFUE