Installation and service instructions
for contractors
VIESMANN
Vitodens 050-W
Type B0HA, B0KA, BPKA, 3.2 to 25 kW
Wall mounted gas condensing boiler
Natural gas and LPG version
Type B0KA-M (for multiple connection), 7.0 to 25 kW
Wall mounted gas condensing boiler
Natural gas and LPG version
Gas Council No.
B0KA: 47-819-55, 47-819-57
B0KA-M: 47-819-56
VITODENS 050-W
6179762 GB 10/2022
Please keep safe.

Table of Contents

Other manuals for Viessmann B0KA

Questions and Answers

  • M
    Mark Strickland Jr.Aug 25, 2025
    How to fix fault F2 on Viessmann B0KA Boiler?
    • W
      William NicholsAug 26, 2025
      If your Viessmann Boiler is showing fault code F2, which indicates the temperature limiter has responded, you should: 1. Check the heating system fill level. 2. Check the circulation pump. 3. Vent the system. 4. Check the temperature limiter and connecting cables.
  • C
    Clifford ContrerasAug 26, 2025
    What should I check if my Viessmann Boiler shows fault F4?
    • G
      gsimpsonAug 26, 2025
      If your Viessmann Boiler displays fault code F4, you should check the gas train (ensure the control voltage is 230 V) and verify the gas supply pressure.
  • L
    Lauren FinleyAug 27, 2025
    How to troubleshoot fault F9 on Viessmann B0KA?
    • J
      Jamie BaileyAug 27, 2025
      If your Viessmann Boiler displays fault code F9, it means the fan speed is too low during burner start. You should check the fan, fan connecting cables, and power supply. Also, check the fan control.
  • D
    Danielle WrightAug 27, 2025
    What does fault F8 mean on a Viessmann B0KA Boiler?
    • W
      Wendy DickersonAug 27, 2025
      If your Viessmann Boiler is displaying fault code F8, which indicates the fuel valve closes too late, you should check the gas train and both control paths.
  • J
    Jacob ElliottAug 28, 2025
    How to fix fault 10 on Viessmann B0KA Boiler?
    • G
      Guy LawrenceAug 28, 2025
      If your Viessmann Boiler shows fault code 10, and the cause is a short circuit or lead break in the outside temperature sensor, you should check the outside temperature sensor and its lead.
  • S
    shannonmooreAug 29, 2025
    What does fault 30 mean on Viessmann Boiler?
    • A
      Andrea ThomasAug 29, 2025
      If your Viessmann Boiler shows fault code 30, caused by a short circuit or lead break in the boiler water temperature sensor, you should check the boiler water temperature sensor.
  • D
    Deborah GomezAug 30, 2025
    What to do if Viessmann B0KA shows fault 51?
    • L
      Lisa MooreAug 30, 2025
      If your Viessmann Boiler shows fault code 51, caused by a short circuit or lead break in the outlet temperature sensor, you should check the sensor.
  • X
    xloveAug 23, 2025
    What causes fault code F4 on a Viessmann Boiler?
    • T
      Timothy HancockAug 25, 2025
      If your Viessmann Boiler displays fault code F4 and there's no flame signal, you should inspect the ignition/ionisation electrode and its connecting cables. Also, verify the gas pressure, gas train, ignition components, ignition module, and ensure the condensate drain is clear.
  • K
    Kim VargasSep 1, 2025
    What causes fault A9 on Viessmann B0KA?
    • D
      David ManningSep 1, 2025
      If your Viessmann Boiler displays fault code A9, which indicates a communication error with the OpenTherm device, you should check the connections and lead. If required, replace the OpenTherm device.
  • J
    James Herrera Jr.Sep 1, 2025
    What does fault b0 mean on a Viessmann Boiler?
    • C
      Charles StaffordSep 1, 2025
      If your Viessmann Boiler displays fault code b0, indicating a short circuit in the flue gas temperature sensor, you should check the sensor.