91
Gas boiler, type B and C, category I
2N
/I
2H
Type B0HA
Rated heating output range (details to
EN 15502)
T
F
/T
R
= 50/30 °C
Natural gas kW 3.2 to 19.0 3.2 to 25.0
LPG kW 3.2 to 19.0 3.2 to 25.0
T
F
/T
R
= 80/60 °C
Natural gas kW 2.9 to 17.0 2.9 to 22.5
LPG kW 2.9 to 17.0 2.9 to 22.5
Communication module (integral)
WiFi frequency band MHz 2400 to 2483.5
Max. transmission power dBm 20
Low power radio frequency band MHz 2400 to 2483.5
Max. transmission power dBm 10
Supply voltage V 24
Power consumption W 4
Electronic temperature limiter setting (TN) °C 91
Electronic temperature limiter setting °C 110
Electronic flue gas temperature limiter setting °C 110
Permissible ambient temperature
During operation °C +5 to +40
During storage and transport °C -5 to +60
Weight
Excl. heating water and packaging kg 35 35
Incl. heating water kg 41 41
Water capacity (excl. diaphragm expansion ves-
sel)
l 3.0 3.0
Max. flow temperature °C 82 82
Max. flow rate
(Limit for the use of hydraulic separation)
l/h See residual head graph
Nominal circulating water volume
At T
F
/T
R
= 80/60 °C
l/h 752 988
Diaphragm expansion vessel
Capacity l 8 8
Pre-charge pressure bar
kPa
0.75
75
0.75
75
Permiss. operating pressure bar
MPa
3
0.3
3
0.3
Connections (with connection accessories)
Boiler flow and return G ¾ ¾
Cold water and DHW G ½ ½
Dimensions
Length mm 300 300
Width mm 400 400
Height mm 700 700
Gas connection R ¾ ¾