Function Code Operat-
ing level
Setting options Delivered
condition
"Reset to default param-
eters"
If "Yes" is set, the current
parameter settings are re-
set to the factory settings
or the settings saved under
code 6204. This does not
include fields such as time
and date, programming
unit, wireless, service/spe-
cial operation, all time pro-
grams and metering func-
tions.
6205 "F2" ■ "No"
■ "Yes"
"No"
"VVS Device ID" 6218 "F2" 00.0 to 99.9 –
"SW version subsys-
tem"
6219 "F2" 00.0 to 99.9 –
"Software version" 6220 "F2" 00.0 to 99.9 –
"Development index" 6221 "F2" 0 to 99 –
"Device hours run"
Note
Hours run are already
shown on delivery, as each
device undergoes a hot
test before shipment.
6222 "F2" 00:00:00 to
20833:00:00 h
"Cylinder forced charg
duration max" (see
page 154)
6282 "F2" 1 to 20 h 2