93
"Holiday program heating circuit 2"
Function Code Operat-
ing level
Setting options Delivered
condition
"Holiday period HC2":
"Start" (Day 1)
652 "E" 01/01 to 31/12 - -.- -
"Holiday period HC2":
"End" (Last day)
653 "E" 01/01 to 31/12 - -.- -
"Holiday operating level
HC2"
658 "E" "Frost protec-
tion"
"Reduced"
"Frost pro-
tection"
"Holiday program heating circuit 3"
Function Code Operat-
ing level
Setting options Delivered
condition
"Holiday period HC3":
"Start" (Day 1)
662 "E" 01/01 to 31/12 - -.- -
"Holiday period HC3":
"End" (Last day)
663 "E" 01/01 to 31/12 - -.- -
"Holiday operating level
HC3"
668 "E" "Frost protec-
tion"
"Reduced"
"Frost pro-
tection"
"Heating circuit 1"
Function Code Operat-
ing level
Setting options Delivered
condition
"Room temperature
comfort setpoint"
710 "E" 6 to 35 °C 20.0
"Room temperature re-
duced setpoint"
712 "E" 6 to 35 °C 14.0
"Room temperature frost
protection setpoint"
714 "E" 4 to 35 °C 4.0
"Heating curve slope"
(see page 81)
720 "F1" 0.10 to 4.00 1.40
"Heating curve displace-
ment" (see page 81)
721 "F1" - 4.5 to 4.5 °C 0.0
"Summer/winter heating
limit" (see page 159)
730 "F1" - - -/8 to 30 °C 18
"24-hour heating limit"
(see page 159)
732 "F2" - - -/- 10 to 10 °C 0