98
Function Code Operat-
ing level
Setting options Delivered
condition
"Screed drying func-
tion" (see page 83)
1150 "F2" "Off"
"Functional
heating"
"Curing heat-
ing"
"Functional +
curing heat-
ing"
"Curing +
functional
heating"
"Manually"
"Off"
"Floor curing setp man-
ually"
1151 "F2" 0 to 95 °C 25
"Flow temp setpoint
screed drying"
1155 "F2" 0 to 95 °C 0
"Screed drying day" 1156 "F2" 0 to 32 days 0
"Floor curing days com-
pleted"
1157 "F2" 0 to 32 days 0
"Heating circuit 2 with
buffer"
The heating circuit is con-
nected to a heating water
buffer cylinder.
1170 "F2" "No"
"Yes"
"Yes"
"Heating circuit 2 with
prim contr/system
pump"
Connecting line to the
heating circuit with/without
upstream control equip-
ment or feed pump.
1172 "F2" "No"
"Yes"
"Yes"
"Optg mode change-
over"
1200 "F2" "None"
"Frost protec-
tion mode"
"Reduced"
"Comfort"
"Automatic"
"None"