VIKING TECHNICAL SUPPORT 1.800.908.0884
18
ELECTRICAL INSTALLATION
MONITORED UL SENSOR CONNECTIONS
!
TECHNICAL TIP: For more information regarding accessory connections to the Control Board
and individual input terminal functions, refer to pages 26-27.
Re-Open (Monitored Input Terminal)
The “Re-Open” input terminal protects
against entrapment in the closing
direction ONLY. Input will reverse the
gate all the way to the Open Limit when a
connected device it triggered. Pages 6-7.
UL (Monitored Input Terminal)
The “UL” input terminal protects against
entrapment in both the opening and
closing directions. Input will reverse
the gate momentarily in the opposite
direction it was traveling when a
connected device it triggered. Pages 6-7.
Check for proper operation:
When a connected device is triggered, the
Re-Open” LED will illuminate and, if more than
one Monitored device connected, the “Stop” LED
will flash rapidly to indicate an input.
! If more than one Monitored device is
connected to this terminal, the “Re-Open” LED
will be illuminated. This alone is inconsequential.
Check for proper operation:
When a connected device is triggered, the
UL” LED will illuminate and, if more than
one Monitored device connected, theStop
LED will flash rapidly to indicate an input.
! If more than one Monitored device is
connected to this terminal, the “UL” LED will
be illuminated. This alone is inconsequential.
NOTE: The “Stop” LED
will be illuminated if
there is a failure with
at least one monitored
entrapment sensor and
the gate operator will
be rendered inoperable.
Relay Terminals
10K Monitored
Power Terminals
Relay Terminals
10K Monitored
Power Terminals