© 2009 Viking Preferred Service
23
Service Diagnostics and Procedures
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless
test procedures require power to be connected. Discharge capacitor through a resistor before attempting
to service. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Access Control Board Assembly
Condition Requirements:
None
1. Remove two screws and lift kick plate from
keyhole screws.
2. Remove two keyhole screws and lower access grill
from range.
3. Remove two screws and slide control assembly
from range.
Note: During installation, make sure the tabs on the
control panel are aligned with the slots on the range.
4. Reverse procedure for installation.
Control Board Removal
Condition Requirements:
Control Board Accessed
1. Mark and disconnect all connectors from control
board and capacitors.
2. Place control board panel assembly on suitable
work surface.
3. Remove ten screws and control board from lower
mounting plate.
4. Reverse procedure for installation.