33
Service Diagnostics and Procedures–Disassembly
Convection Fan Cover Removal
Condition Requirements:
One Rack Support Removed
1. Remove three screws and fan cover from oven
cavity.
2. Reverse procedure for installation.
Smoke Eliminator Removal
Condition Requirements:
Convection Fan Cover Removed
1. Remove the two screws that hold the smoke
eliminator to the top, left, rear corner of the
oven liner.
2. Pull down the smoke eliminator to remove from
oven liner.
3. Reverse procedure for installation.
Convection Fan Assembly Removal
Condition Requirements:
Convection Fan Cover Removed
1. Remove six screws and set convection fan
assembly on oven liner.
2. Disconnect connector and lift convection fan
assembly from oven cavity.
Note: The mounting hole pattern for the
convection fan assembly is NOT symmetrical.
Line up holes before installing.
3. Reverse procedure for installation.
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless
test procedures require power to be connected. Discharge capacitor through a resistor before attempting
to service. Ensure all ground wires are connected before certifying unit as repaired and/or operational.