© 2009 Viking Preferred Service
47
Component Testing
Component Volts Ohms Amps Test Location
Cooling Fan 12VDC 9150 _ 0.38 8xÇÊÊÌiÀÊ>À`
LR/RR Inductor 240 N/A N/A 8Ç8Ê>ÌÊ«ÜiÀÊL>À`Ê
LF/RF Inductor 240 N/A N/A 8È8nÊ>ÌÊ«ÜiÀÊL>À`
Power Board 240 N/A N/A Black to Blue at board
Filter Board 240 N/A N/A £Ê8xä®Ê>`ÊÓÊ8xÓ®Ê>ÌÊL>À`
Induction Switch N/A
11690 Ω
9430 Ω
9003 Ω
7850 Ω
6600 Ω
3840 Ω
9.6 Ω
N/A Off traces 2-3 at switch
Simmer traces 2-3 at switch
Low traces 2-3 at switch
Med-Lo traces 2-3 at switch
Medium traces 2-3 at switch
Med-HI traces 2-3 at switch
HI traces 2-3 at switch
Bake Element 240
38.3 Ω Outer
37.8 Ω Inner
6.3
6.3
K17 yellow – P5 blue
K17 yellow – P6 purple
Broil Element 240
34.3 Ω Outer
29.3 Ω Inner
7.0
8.2
K17 yellow – P6 grey
K17 yellow – P6 purple
Convection Element 240
18.3 Ω
13.1 K17 yellow - P2 white
Convection Motor 240
103.6
2.3 P1 black – P4 blue CCW
P1 black – P4 grey CW
Sensor 5VDC
1100 Ω at 75˚ F
N/A P15 pin1 – pin2
Blower Motor 120 18.2 6.6 N – P11 white
Door Latch Motor 240 12.1K _ 0.02 P1 black – P12 white
Door Latch Switch
(Door Unlocked)
5VDC
0VDC
Open
Closed
N/A P19 green – orange
P19 green – blue
Door Latch Switch
(Door Locked)
0VDC
5VDC
Closed
Open
N/A P19 green –orange
P19 green – blue
Cycle Light 240 Open N/A P1 black – P12 grey
Clean Light 240 Open N/A P1black – P12 purple
Oven Light Switch–Off
(Door Closed)
16VDC Open
(P20 brown–purple)
N/A P20 brown – purple
Oven Light Switch–On
(Door Closed)
0VDC
0 Ω
(P20 brown–purple)
N/A P20 brown – purple
Oven Door Switch
(Door Open)
0VDC Open
(P20 brown–purple)
N/A P20 brown – grey
Oven Door Switch
(Door Closed)
16VDC Open
(P20 brown–grey)
N/A P20 brown – grey
Service Diagnostics and Procedures