Idicator, Inductor, Filter and Power Board
Removal (continued)
10. Remove six screws securing generator cover
(generator cover is suspended, support
generator cover prior to removing screws).
11. Remove generator cover. Filter and power
board are now accessible.
12. Reverse procedure to reassemble.
Interior Light bulb Replacement
1. Unsnap glass light cover using a screwdriver in
the access groove.
2. Firmly grasp light bulb and pull out.
3. Replace with halogen bulb using volt and
wattage requirements listed on glass cover.
4. Replace the light cover by snapping glass cover
onto metal box.
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless
test procedures require power to be connected. Discharge capacitor through a resistor before attempting
to service. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Power Board
Filter Board
CAUTION
DO NOT touch bulb with bare hands. Clean off
any signs of oil from the bulb and handle with
a soft cloth.
12
3
4
Generator Cover