Manual BG41/BG42/BG43 Software
Rev. 99/49 4-53
PAFE
Contains a byte for issuing an error number. PAFE provides the value 0, the
parameter details are therefore correct. A value unequal to 0 represents an error.
A value unequal to 0 represents an error, the given interface is not initialised.
PAFE Error codes registered by:
0 No error Data handling block
1 Wrong command Interface building block
2 Wrong channel number Interface building block
3 Wrong procedure number Interface building block
4 Wrong initialisation Interface building block
5 Wrong clock command Interface building block
6 Invalid clock data Interface building block
7 Wrong parametrizing Interface building block
8 Wrong number of parameters Interface building block
9 Not used
10 Not used
11 Invalid value on the operands ADRE Data handling block
12 Invalid value on the operands SSNR Data handling block
13 Invalid value on the operands BAUD Data handling block
14 Invalid value on the operands PRIO Data handling block
15 Invalid value on the operands BLOC Data handling block
16 Undefined answer from the interface Data handling block
building block
17 Invalid value in high byte FORM Data handling block
PROZ <> 3964 or 3964R
18 Character delay time is 0 Data handling block
19 Acknowledgement delay time is 0 Data handling block
NEUS
If the data handling block is run with a set new star bit, the building block is
blocked for all SPS accesses. By loading the FB28 with a set new start bit, the
building block is once again released.