Handling with VIPA data handling blocks Manual BG41/BG42/BG43
4-54 Rev. 99/49
The data handling block examines the parametrized values at the following limits:
ADRE F080...F1FC
SSNR 1...2 (3)
BAUD 1...11
FORM Data handling block examines
High-Byte: 0 = 3964
1 = 3964R
Low Byte: Transmission format of the serial interface
PRIO 0/1
BLOC 16...128, always even-numbered
ZVZ 1...65535
QVZ 1...65535
Example: FB27 (SYNCHRON)
SPA FB27
NAME :SYNCHRON
ADRE :KH F080 The address set with DIL switches
SSNR :KF +1 Interface number 1,2 (3)
BAUD :KF +10 Baud rate code 1...11 (10 = 9600baud)
FORM :KM 00000001 11111100 Transmission format:8bit,even parity,2 stop
PRIO :KF +0 0=low, 1=high priority
BLOC :KF +128 Block size in bytes (always even-numbered!)
ZVZ :KF +20 200ms Character delay time (Value*10ms)
QVZ :KF +500 5000ms Acknowledgement delay time
(Value*10ms)
PAFE :MB 5 Byte for the output of an error number
NEUS :M 1.0 Blocking of the building block