- 94 -
www.vivotek.com
T: 886-2-82455282
F: 886-2-82455532
triggered state.
PARAMETER VALUE DESCRIPTION
0 – inactive, normal state
do<num>
0, 1
1 – active, triggered state
return
<return page> Redirect to the page <return page> after the
parameter is assigned. The <return page> can be
a full URL path or relative path according the the
current path. If you omit this parameter, it will
redirect to an empty page.
Example: Drive the digital output 1 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do1=1
Query status of the digital input
Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n
\r\n
[di0=<state>]\r\n
[di1=<state>]\r\n
[di2=<state>]\r\n

Table of Contents