8
Voith Turbo H + L Hydraulic GmbH & Co. KG
25000057510-TED-ENX-04
Preparation
•
Assemble the coupling parts without
unnecessary force (i.e. without
knocks or pressing). Use the thread
tapped hole in the shaft end.
•
Check that the direction of rotation of
the drive and the pump match.
•
Note the arrow indicating the direc-
tion of rotation on the pump housing
or the rating plate.
•
Attach the pump and ensure there
are no axial or transverse forces
acting on the drive (coupling direc-
tion).
• Remove the core plugs on the pump.
•
Prell the pump with operating uid
via the suction port.
•
Relieve the delivery pipe, set the
directional control valve and/or pres-
sure limiting valve to unpressurized
circulation (note the charging pressu-
re through any existing check valves).
• Pipelines must be leak-proof.
•
Delivery pipes must not be lled with
operating uid.
Internal gear pumps