EasyManua.ls Logo

VTI Instruments EX1629 - Page 100

Default Icon
346 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VTI Instruments Corp.
100 EX1629 Command Set
Command
Description
vtex1629_get_lxibus_output
Queries and returns the output state of each of
the channels on the LXI Trigger Bus.
vtex1629_get_pattern_arm_configuration
Queries and returns the EX1629’s current
configuration for the pattern arm mode of
operation.
vtex1629_get_pattern_trig_configuration
This queries and returns the EX1629’s current
configuration for the pattern trigger mode of
operation.
vtex1629_get_poisson_ratio
Queries and returns the Poisson ratio for a
specific channel. This is one of the parameters
used in EU conversion calculations.
vtex1629_get_sample_clock_source
Queries and returns the configured sample clock
source.
vtex1629_get_sample_count
Queries and returns both the pre- and post-
trigger sample counts for the EX1629.
vtex1629_get_sample_frequency
Queries and returns the currently configured
sampling frequency for all channels on the
EX1629.
vtex1629_get_scanlist
Queries and returns a list of channels currently
configured to be sampled in the data acquisition
process.
vtex1629_get_selfcal_status
Queries and returns self-calibration failure
status for the selected channels
vtex1629_get_settling_time
Queries and returns the current settling time for
a particular channel.
vtex1629_get_shunt_enabled
Queries and returns the enabled status of a
particular channel's shunt resistor.
vtex1629_get_shunt_source
Queries and returns the shunt source for a
particular channel.
vtex1629_get_shunt_value
Queries and returns a shunt resistor value based
on a given channel and shunt source.
vtex1629_get_stored_config_digest
Retrieves the digest of the instrument
configuration saved in non-volatile memory.
vtex1629_get_strain_units
Queries and returns the configured strain units
for a given channel.
vtex1629_get_synch_source
Queries and returns the synchronization source.
vtex1629_get_tare
Reads the currently configured tare value for a
specific channel
vtex1629_get_teds_data
Returns the TEDS data for a given channel.
vtex1629_get_trigger_count
Queries and returns the currently configured
trigger count for the EX1629.
vtex1629_get_trigger_delay
Queries and returns the trigger delay for the
EX1629.
vtex1629_get_trigger_source
Queries and returns the current setting for the
trigger source.
vtex1629_get_trigger_timer
Queries and returns the trigger system timer for
the EX1629.
vtex1629_get_unstrained_voltage
Queries and returns the unstrained voltage
currently configured for a given channel.
vtex1629_identify_sensor
Controls the activity of a sensor-linked LED.
vtex1629_init
Opens a session with the instrument and returns
a session handle.
vtex1629_load_stored_config
Applies the stored configuration to the
instrument.
vtex1629_lock
Attempts to acquire a lock on the instrument.
vtex1629_measure_confidence
Measures the indicated bridge parameter to
indicate measurement confidence.
vtex1629_measure_excitation_voltage
Measures the total excitation voltage for a list of
channels.

Table of Contents