VTI Instruments Corp.
100 EX1629 Command Set
vtex1629_get_lxibus_output
Queries and returns the output state of each of
the channels on the LXI Trigger Bus.
vtex1629_get_pattern_arm_configuration
Queries and returns the EX1629’s current
configuration for the pattern arm mode of
operation.
vtex1629_get_pattern_trig_configuration
This queries and returns the EX1629’s current
configuration for the pattern trigger mode of
operation.
vtex1629_get_poisson_ratio
Queries and returns the Poisson ratio for a
specific channel. This is one of the parameters
used in EU conversion calculations.
vtex1629_get_sample_clock_source
Queries and returns the configured sample clock
source.
vtex1629_get_sample_count
Queries and returns both the pre- and post-
trigger sample counts for the EX1629.
vtex1629_get_sample_frequency
Queries and returns the currently configured
sampling frequency for all channels on the
EX1629.
Queries and returns a list of channels currently
configured to be sampled in the data acquisition
process.
vtex1629_get_selfcal_status
Queries and returns self-calibration failure
status for the selected channels
vtex1629_get_settling_time
Queries and returns the current settling time for
a particular channel.
vtex1629_get_shunt_enabled
Queries and returns the enabled status of a
particular channel's shunt resistor.
vtex1629_get_shunt_source
Queries and returns the shunt source for a
particular channel.
Queries and returns a shunt resistor value based
on a given channel and shunt source.
vtex1629_get_stored_config_digest
Retrieves the digest of the instrument
configuration saved in non-volatile memory.
vtex1629_get_strain_units
Queries and returns the configured strain units
for a given channel.
vtex1629_get_synch_source
Queries and returns the synchronization source.
Reads the currently configured tare value for a
specific channel
Returns the TEDS data for a given channel.
vtex1629_get_trigger_count
Queries and returns the currently configured
trigger count for the EX1629.
vtex1629_get_trigger_delay
Queries and returns the trigger delay for the
EX1629.
vtex1629_get_trigger_source
Queries and returns the current setting for the
trigger source.
vtex1629_get_trigger_timer
Queries and returns the trigger system timer for
the EX1629.
vtex1629_get_unstrained_voltage
Queries and returns the unstrained voltage
currently configured for a given channel.
Controls the activity of a sensor-linked LED.
Opens a session with the instrument and returns
a session handle.
vtex1629_load_stored_config
Applies the stored configuration to the
instrument.
Attempts to acquire a lock on the instrument.
vtex1629_measure_confidence
Measures the indicated bridge parameter to
indicate measurement confidence.
vtex1629_measure_excitation_voltage
Measures the total excitation voltage for a list of
channels.