EX1629 Command Set 99
Command
Description
vtex1629_get_confidence_reporting_mode
Queries and retrieves the reporting mode for
confidence limit checking.
vtex1629_get_current_config_digest
Retrieves the digest for the current instrument
configuration.
vtex1629_get_dio_bank0_direction
Indicates whether bank zero of the digital I/O is
configured as input or output.
vtex1629_get_dio_bank0_pullup
Queries and returns the pull-up mode for bank
zero of the digital I/O.
vtex1629_get_dio_bank1_direction
Indicates whether bank one of the digital I/O is
configured as input or output.
vtex1629_get_dio_bank1_pullup
Queries and returns the pull-up mode for bank
one of the digital I/O.
vtex1629_get_dio_config_events
Queries and returns the current setting for DIO
event transitions.
vtex1629_get_dio_input
Queries and returns the current input state of
both banks of the digital I/O.
vtex1629_get_dio_output
Queries and returns the current programmed
output state of both banks of the digital I/O.
vtex1629_get_dsp_version
Returns the DSP version information for a given
analog board.
vtex1629_get_EU_conversion
Reads the EU conversion type for a specific
channel.
vtex1629_get_euconv_dynamic_excitation_enabled
Queries and returns the dynamic excitation EU
conversion state
vtex1629_get_euconv_excitation
Queries and returns the current value used in
EU conversions for the excitation voltage for a
given channel.
vtex1629_get_excitation
Queries and returns the programmed excitation
voltage for a given channel.
vtex1629_get_excitation_enabled
Queries and returns the enabled status of the
excitation voltage for a specific channel.
vtex1629_get_fifo_count
Queries the EX1629 for the current FIFO page
count.
vtex1629_get_gain
Reads the specified channel's current signal
conditioning gain.
vtex1629_get_gauge_factor
Queries and returns the gage factor for a
specific channel. This is one of the parameters
used in EU conversion calculations.
vtex1629_get_half_bridge_lead_wire_desensitization
Queries and returns the lead wire desensitization
factor for the specified channel.
vtex1629_get_IIR_filter_configuration
Queries and returns the IIR filter configuration
parameters for a given channel.
vtex1629_get_input_multiplexer
Queries and returns the input multiplexer
source.
vtex1629_get_instrument_serial_number
Returns the instrument's serial number
vtex1629_get_lead_wire_resistance
Queries and returns the currently defined lead
wire resistance value.
vtex1629_get_linearscaling_configuration
Returns the slope (m) and intercept (b)
parameters for a given channel.
vtex1629_get_lxi_limit_event_enabled
Returns which measurement channels are
enabled for Limit Events on the specified LXI
Trigger Bus line.
vtex1629_get_lxi_limit_event_latch
Returns a mask indicating which LXI trigger
lines will be latched for LXI Limit Event
outputs.
vtex1629_get_lxibus_configuration
Queries and returns information pertaining to a
specified LXI Trigger Bus channel.
vtex1629_get_lxibus_input
Queries and returns the input state of each of the
channels on the LXI Trigger Bus.