102 EX1629 Command Set
Command
Description
vtex1629_set_confidence_limit
Sets the minimum and maximum values for
confidence data limit checking
vtex1629_set_confidence_reporting_mode
Sets the reporting mode for confidence limit
checking.
vtex1629_set_dio_bank0_direction
Sets the direction of bank zero of the digital I/O
as input or output.
vtex1629_set_dio_bank0_pullup
Sets the pull-up mode for bank zero of the
Digital I/O to passive or active.
vtex1629_set_dio_bank1_direction
Sets the direction of bank one of the digital I/O
as input or output.
vtex1629_set_dio_bank1_pullup
Sets the pull-up mode for bank one of the
Digital I/O to passive or active.
vtex1629_set_dio_config_events
Sets the conditions under which DIO event
transitions will occur.
vtex1629_set_dio_output
Sets the programmed output state for both
digital I/O banks.
vtex1629_set_EU_conversion
Set the EU conversion type for a given list of
channels.
vtex1629_set_euconv_dynamic_excitation_enabled
Sets the dynamic excitation EU conversion
state.
vtex1629_set_euconv_excitation
Manually sets the excitation voltage to be used
in EU conversions for a particular list of
channels.
vtex1629_set_excitation
Sets the programmed excitation voltages for a
given list of channels.
vtex1629_set_excitation_enabled
Enables or disables the excitation voltages for a
list of channels.
vtex1629_set_gain
Sets the signal conditioning gain for a given list
of channels.
vtex1629_set_gauge_factor
Sets the gage factor for a list of channels.
vtex1629_set_half_bridge_lead_wire_desensitization
Sets the lead wire desensitization factor a given
list of channels.
vtex1629_set_IIR_filter_configuration
Configures the IIR filters for a given list of
channels.
vtex1629_set_input_multiplexer
Sets the input multiplexer source.
vtex1629_set_lead_wire_resistance
Sets the resistance of the lead wire.
vtex1629_set_linearscaling_configuration
Sets the coefficients for linear scaling for
multiple channels
vtex1629_set_lxi_limit_event_enabled
Sets which measurement channels are enabled
for Limit Events on the specified LXI Trigger
Bus line.
vtex1629_set_lxi_limit_event_latch
Sets which LXI Trigger Bus lines will be
latched for LXI Limit Event outputs.
vtex1629_set_lxibus_configuration
Configures several characteristics of a specific
LXI Trigger Bus channel.
vtex1629_set_lxibus_output
Configures the output state of each of the LXI
Trigger Bus channels.
vtex1629_set_pattern_arm_configuration
Configures the EX1629’s pattern arm mode of
operation.
vtex1629_set_pattern_trig_configuration
Configures the EX1629’s pattern trigger mode
of operation.
vtex1629_set_poisson_ratio
Sets the Poisson ratio for a list of channels
vtex1629_set_sample_clock_source
Sets the sample clock source.
vtex1629_set_sample_count
Sets both the pre-trigger and the post-trigger
sample count for the EX1629.
vtex1629_set_sample_frequency
Sets the sampling frequency of all channels of
the EX1629.
vtex1629_set_scanlist
Defines a list of channels which will be sampled
in the data acquisition process.