EasyManua.ls Logo

WABCO TEBS E1 - Page 76

WABCO TEBS E1
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
TEBS E
GIO functions
76
Connecting the components
Extract from diagram 841 802 150 0
Item
Component Figure Part number
1 TEBS E Modulator (Premium/Standard) 480 102 0.. 0
2 TASC
A precise description of the device is located in the catalogue ‘TASC
Trailer Air Suspension Control - Function and Installation’, see chap-
ter 4 ‘Introduction’, page 12 => Section „Mor
e information’.
463 090 012 0 (1-circuit;
RTR, Resting in lowered
position)
463 090 020 0 (2-circuit;
RTR, Resting in lowered
position, with fittings and test
connection)
463 090 021 0 (2-circuit;
RTR, Resting in lowered
position, with fittings)
463 090 023 0 (2-circuit;
RTR, Resting in lowered
position)
463 090 123 0 (2-circuit;
RTR, dead-man's safety
system for stroke > 300 mm)
3 Standard cable for lifting axle, RTR
449 443 ... 0
Parameter setting
The setting is done via tab 4, Standard functions.
The GIO slots to use are defined in tab 11, connector.

Table of Contents

Related product manuals