EasyManua.ls Logo

WABCO TEBS E4 - Diagnostic Hardware

WABCO TEBS E4
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TEBS E
11
Workshop notes
185
11.3 Diagnostic Hardware
The TEBS E only enables diagnosis via one of the CAN interfaces, see following
options.
The CAN interface conforming to ISO 11898 can be used connecting SUBSYS-
TEMS e.g. IVTM, Telematics, SmartBoard or ELEX.
For further information please refer to the document ‘Diagnosis – Soft-
ware/Hardware’, see chapter 4 ‘Introduction’, page 12 => Se
ction ‘Further informa-
tion’.
Option 1 - diagnosis conforming to ISO 11992 (CAN 24 V); via the 7-pin ISO 7638 CAN connection
Requirements Diagnostic Hardware
ISO 7638 disconnecting adapter with
CAN plug-in socket
446 300 360 0
Diagnostic Interface (DI-2)
with USB port
(for connection to PC)
446 301 030 0
CAN diagnostic cable
446 300 361 0 (5 m)
or
446 300 362 0 (20 m)
Option 2 - Diagnosis according to ISO 11898 (CAN 5 V): via an external diagnosis connection
Requirements Diagnostic Hardware
External diagnostic socket with yellow
cap
Only TEBS E Modulators (Premium)
449 611 ... 0
Diagnostic Interface (DI-2)
with USB port
(for connection to PC)
446 301 030 0
CAN diagnostic cable
446 300 348 0
Do not use the USB interface with 5 V CAN-Bus converter.
Diagnosis
A system diagnosis must be carried out every time anything unusual is noticed in
the system or a warning lamp / fault indicator lights up.
Currently faults as well as intermittent ones are stored in the TEBS E diagnostic
memory and displayed via the TEBS E Diagnostic Software. The Diagnostic Soft-
ware provides instructions for a repair.
Once a fault has been eliminated, the diagnostic memory should always be cleared.

Table of Contents

Related product manuals